DAC (Digital to Analog)
Ver: 0.01.000 February 17, 2011
Original Release
DIO (Digital I/O)
Ver: 0.05.000 November 8, 2011
Added pulse/PWM output feature.
Ver: 0.04 May 13, 2010
Added counting feature.
Ver: 0.03 November 18, 2008
Initial release
DLC (Digital Load Cell)
Ver: 1.00.010 May 1, 2019
Improved CAN bus recovery in case of interruption of V+ or V- line. Added support for new diagnostics screen "DLC Card Communications Error Counts". Fixed issue that iSite network connection may not recover automatically if network is interrupted and then reconnected, or if DHCP assigns a new IP address.
Ver: 1.00.001 October 29, 2018
Fixed issue that if previously configured for more cells, and then changed to fewer cells the calibration may not properly set zero.
Ver: 1.00.000 October 25, 2018
Initial Release
ICAN (ICAN Board)
Ver: 1.00 May 27, 2010
Original Release
SIB (Scale Interface Board)
Ver: 1.10.000 November 17, 2023
Fix for previous version 1.09. Auto-zero could sometimes cause delay of several seconds writing EEPROM and in some cases especially if power cycled memory could be corrupted causing loss of calibration and all settings to return to defaults.
Ver: 1.09.000 May 16, 2022
No operational change, just recompiled and linked for DN microcontroller. It is still compatible with DZ microcontroller.
Ver: 1.08.000 June 29, 2016
Improved zeroing to not write updates to the internal EEPROM as often. Previously, in some cases with auto-zero enabled frequent zeroing could wear out the EEPROM prematurely.
Ver: 1.07.000 July 3, 2012
Changed version number to be consistent with new standard. Operation is identical to version 0.07 except for output of version information.
Ver: 0.07 May 6, 2011
Added FIR filter option. Break Range 0 = always on, Value 2 - 64.
Ver: 0.06 November 18, 2008
Clear weight average after calibration
Ver: 0.05 September 17, 2008
Changed default configuration parameters for board test.
Ver: 0.04 July 31, 2008
Added units labels to board parameters.