wiki:Docs/User/FullUpdate/VersionHistory/Loader

Version 5 (modified by Don Wilson, 6 years ago) ( diff )

--

Loader

Ver: 1.09.012 October 29, 2018

Added digital cell diagnostics, Smart Cal, etc...

Ver: 1.09.009 August 26, 2014

Added "Startup Settings" option to the "Preferences" menu. This option provide a prompt "Auto start time" to set the starting value for the count-down to automatically start application mode. The option "Auto start always" is provided. Selecting "Yes" will cause the count-down to start again if you return to the main screen from another loader screen. The "Bypass Update and Test Option" prompt may be selected "Yes" to prevent the "U = Update T = Test" from appearing when starting application mode. Added “Trim” column to ICAN individual cell fine span screen. The "Trim" column will show the change to the cell trim as adjustments are made. The coarse span adjustment keys are changed from '+' and '-' to ‘C’ and ‘V’ to eliminate problems with getting the shift state wrong

Ver: 1.09.007 April 18, 2013

Added prompts to network configuration screen to allow web server port "P:" to be specified and "NAND:" to be selected "Yes" or "No". If nand is selected web server files will be served from nand to allow customization.

Ver: 1.09.006 February 15, 2013

Improved DAC setup.

Ver: 1.09.004 July 18, 2012

Updated to display verisons in xx.yy.zzz format where xx is metrologically significant change. Updated to set OPI CTS to receive mode to correspond to main board update to use RTS/CTS to signal start of message. Improved ICAN diagnostics - Will display message to check cable and power when CAN bus error occurs.

Ver: 1.08v October 12, 2011

Fixed problem that with more than six scale cards the parameters screen might incorrectly show and set the parameters for scale six if scale seven or above is selected.

Ver: 1.08u May 13, 2011

Updated to allow setting SIB filter type FIR or IIR for SIB cards version 0.07 or above. Modified network setup to not show telnet option if OS version is less then 2.6.26.

Ver: 1.08s Octboer 29, 2010

Updated main menu so option "3." is "Legal metrology information / Setup". When this is selected the options "1. View event counters", "2. View certificates / ID information" and "3. Setup menu" are shown. Options 1 and 2 are not password protected. Password will be prompted for option 3 on first access unless default operator is set to ADMIN.

Ver: 1.08r Octboer 19, 2010

Improved ICAN diagnostics and fine span to multiply weight values by interval to show weights in calibrated weight units. Added feature to fine span cells to select multiple cells by pressing SPACE to allow multiple cells to be tweaked up or down simultaneously. Added ICAN option to show box status. DIO test will now reset outputs after test complete.

Ver: 1.08p September 7, 2010

Improved ICAN setup to display a message when the NOVRAM is cleared and after a time delay go back to setup menu. This eliminates problem of the cell assignment display showing wrong number of cells if you do not ESCAPE out and go back in.

Ver: 1.08o July 26, 2010

Fixed problem with DAC output level.

Ver: 1.08m July 16, 2010

Improved “Update Software Menu” to show warning message before existing OS is erased (Continue Y/N?).

Ver: 1.08k May 24, 2010

Added ICAN and DAC support. Fixed problem with 12 hour mode time may show as 0:00 instead of 12:00. Improved totalizer calibration parameter prompting to allow one set of inputs to configure all scales in totalizer.

Ver: 1.07k Dec 17, 2008

Added OIML certification number to information display.

Ver: 1.07 November 20, 2008

Corrected problem with main board COM3 not being set to correct baud based on preference setting.