MnBdProcess * DEPRECATED - New apps should use StartRepeatMulti *
Requests weight and reads the from the main board based on some internal scheduling.
int MnBdProcess(void);
Parameters
Function does not accept any parameters.
Return Value
Function returns mnbdProcWtRcv when new weight data is available, mnbdIORcv when new IO status information is available.
Remarks
This is usually called from within the main screen process event.
Examples
EVENT(MainScreenProcess) { int n = MnBdProcess(); if(n == mnbdProcWtRcv) { if(IsGrossWtChanged(1)) { DisplayText(0, 40, GetChangedGrossWt(1), 0, BIG_FONT); } } return 0; }
See Also
Last modified
5 years ago
Last modified on 03/16/20 14:14:42
Note:
See TracWiki