Stop a digital output pulse for the a DIO option card.
int StopDIOPulse(int bd, int out);
Parameters ¶
- bd - number of digital output card (main board output is not supported for pulse)
- output - output number (outputs 1 - 4) only are supported
Return Value ¶
- Returns the result - OK success
Remarks ¶
Requires main board version 1.19 and DIO card firmware version 0.05 or greater. The main board or option card must already be opened by calling OpenMnBd first. The call does a wait for acknowledgement. If the application is using main board communication events these events may be called during the wait for acknowledgement.
Examples ¶
if(StopDIOPulse(1, 1) == OK) DisplayText(0, 0, "Pulse output stopped");