Changes between Version 23 and Version 24 of Docs/User/FullUpdate/VersionHistory


Ignore:
Timestamp:
01/28/11 11:11:57 (14 years ago)
Author:
Don Wilson
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Docs/User/FullUpdate/VersionHistory

    v23 v24  
    66The information below shows update information organized into update packages. It is generally recommended that 825 indicators should be updated using the update packs.
    77
    8 === Update Pack 2010-01-28 ===
     8=== Update Pack 2011-01-28 ===
    99[http://tech.825spectrum.com/trac/raw-attachment/wiki/Docs/User/FullUpdate/VersionHistory/update825-2011-01-28.zip OS: 2011-01-28 Loader: 1.08s MB: 1.17]
    1010 * '''OS -''' Fixed problem that weight server may not work with serial communications after previous update. The weight server is moved out of the kernel and to the /mnt/nand/bin location for easier maintenance. Fixed problem with stty on startup causing on-demand communications to buffer input and require carriage return before input is accepted. This is fixed by adding "-icanon -iexten -echo -echoctl -echonl" to default options generated by stty when -Z option is used. Added startup check for /mnt/nand/cfg/boa.conf and if found it will be copied to /etc. This will allow web server port or other settings changes to be stored in nand.