Changes between Version 9 and Version 10 of Docs/User/FullUpdate/VersionHistory


Ignore:
Timestamp:
10/21/10 11:03:41 (14 years ago)
Author:
Don Wilson
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Docs/User/FullUpdate/VersionHistory

    v9 v10  
    44The information below shows update information organized into update packages. It is generally recommended that 825 indicators should be updated using the update packs.
    55
    6 === Update Pack 2010-09-09 ===
     6=== Update Pack 2010-10-21 ===
     7==== OS: 2010-10-21 Loader: 1.08r MB: 1.17 ====
     8'''OS -''' Fixed problem with weight server remote control showing blank screen and not accepting keypresses. Added feature to weight server remote control. Weight server remote control enabled can be determined by checking for existence of /tmp/wtsvr_rc_port file; when the remote control is enabled the file will contain the IP port number for remote control. Whether any clients are connected can be determined by checking for existence of /tmp/wtsvr_rc_clients file; when any clients are connected file will contain list of client IP addresses.
     9'''Loader -''' Improved ICAN diagnostics and fine span to muliply weight values by interval to show weights in calibrated weight units. Added feature to fine span cells to select muliple cells by pressing SPACE to allow muliple cells to be tweaked up or down simultaneously. Added ICAN option to show box status. DIO test will now reset outputs after test complete.
     10
     11
    712==== OS: 2010-08-18 Loader: 1.08p MB: 1.17 ====
    813'''OS -''' Fixed problem with usb keyboard driver that if key is held down when key repeat starts indicator may crash.
     
    3439
    3540=== OS ===
     41
     42==== Ver: 2010-10-21  October 21, 2010 ====
     43Fixed problem with weight server remote control showing blank screen and not accepting keypresses. Added feature to weight server remote control. Weight server remote control enabled can be determined by checking for existence of /tmp/wtsvr_rc_port file; when the remote control is enabled the file will contain the IP port number for remote control. Whether any clients are connected can be determined by checking for existence of /tmp/wtsvr_rc_clients file; when any clients are connected file will contain list of client IP addresses.
    3644
    3745==== Ver: 2010-08-18  August 18, 2010 ====
     
    7280
    7381=== Loader (OPI Boot loader) ===
     82
     83==== Ver: 1.08r  Octboer 19, 2010 ====
     84Improved ICAN diagnostics and fine span to muliply weight values by interval to show weights in calibrated weight units. Added feature to fine span cells to select muliple cells by pressing SPACE to allow muliple cells to be tweaked up or down simultaneously. Added ICAN option to show box status. DIO test will now reset outputs after test complete.
    7485
    7586==== Ver: 1.08p  September 7, 2010 ====