StopDIOPulse
Stop a digital output pulse for the a DIO option card.
int StopDIOPulse(int bd, int out);
Parameters
- bd - number of digital output card (main board output is not supported for pulse)
- output - output number (outputs 1 - 4) only are supported
Return Value
- Returns the result - OK success
Remarks
Requires main board version 1.19 and DIO card firmware version 0.05 or greater. The main board or option card must already be opened by calling OpenMnBd first. The call does a wait for acknowledgement. If the application is using main board communication events these events may be called during the wait for acknowledgement.
Examples
if(StopDIOPulse(1, 1) == OK) DisplayText(0, 0, "Pulse output stopped");