Docs/825gen2/Dev/UpdatingLegacyApps
v136 v137 57 57 23. A few source code changes may be needed for proper operation on the 825 Gen2. If the app has USB import/export features it may use a fixed path "/mnt/fl1" for the USB drive. The USB drive path will not be the same on the 825 Gen2. Search the project for the string "/mnt/fl1" to find any code that should be changed. The library lib825ev has a function called [wiki:Docs/Prog/Manual/ApplicationLibraries/lib825ev/File/FindFlashDrive FindFlashDrive] for the 825 Gen2 to get the path string. The path may be similar to "/run/media/sda1" but it is best to use the !FindFlashDrive function instead of a hard coded path. 58 58 59 24. The 825 Gen2 defaults to 12 hour time which requires AM/PM to59 24. The 825 Gen2 defaults to 12 hour time which requires AM/PM labels to show the date/time. Legacy 825 indicators defaulted to 24 hour time. Many legacy apps do not allow for enough space to display the AM/PM labels. So slight modification of the date/time display code may be needed to accommodate 12 hour time. 60 60 61 61 25. Also (probably rare) if the app communicates with another system by serial port, network, or file import/export that interprets the data content as binary integers, floats, etc... it may be necessary to make changes to account for different [https://en.wikipedia.org/wiki/Endianness endianness]. The 825 Gen2 is ARM-64 little-endian, The Legacy 825 is Coldfire big-endian.