wiki:Docs/Prog/Manual/ApplicationLibraries/lib825ev/Weight/SetWIM

Version 4 (modified by Don Wilson, 14 years ago) ( diff )

--

SetWIM

Setup for high speed buffered weight reading

void SetWIM(int nScale, int nOnThres, int nOffThres, int nCnt)

Parameters

  • nScale - scale number

Return Value

Function does not return a result

Remarks

This function allocates memory to accommodate the specified count of weight values. When the gross weight exceeds the on threshold the buffering begins. Gross weights are recorded into the buffer. When the gross weight drops below the off threshold the buffering stops. This allows the application to process many gross weights in an array for high speed.

Example

extern int g_nRepWtIntv;

int nOnThres = 1000;
int nOffThres = 800;
int nNumWtsToBuffer = 1000;
SetWIM(1, nOnThres, nOffThres, nNumWtsToBuffer);

SleepSeconds(1);

g_nRepWtIntv = REP_INTV_SAMPLE_RATE;
MnBdReqeust(1, MNBD_REQ_REP_WT, NO_WAIT_ACK);

// Weights should now be coming in at the sample rate
// Weights above the threshold will be recorded into the WIM buffer

See Also

Note: See TracWiki for help on using the wiki.