  • Docs/825gen2/Updating/SDCardUpdate

    v1 v2  
    88||Loader||1.21.001-2022.04||
    99Diagnostics Menu - OS image build date 2024-08-16
     10
     11This folder contains a 7-zip compressed image file.
     12Extract this file to a local drive to obtain the microSD card image.
     13Use a program such as BelenaEtcher to write the image to a microSD card.
     14
     15**** microSD card will be fully overwritten - any existing files on card
     16will be lost ****
     17
     18**** Be sure to check that correct destination drive is selected in
     19BelenaEtcher before performing write to microSD card ****
     20
     21(Preferred microSD card size at least 16G).
     22
     23To install to 825:
     24
     251. Power off 825.
     262. Insert microSD card in mainboard.
     273. Insert boot jumper.
     284. Power on 825.
     295. Press "LEGAL METROLOGY INFORMATION / SETUP" button
     306. Press "SETUP MENU" button
     317. Press keyboard button to show on-screen keyboard and type "ADMIN"
     328. Press down arrow and type password "81440"
     339. Press "Install from microSD"
     3410. Press "Yes", press down arrow and type "CONFIRM". Press "ENTER".
     3511. Installation messages will appear for several minutes.
     3612. When finished display will show "Yocto Installed Successfully"
     3713. Wait for screen to return to setup menu
     3814. Power off 825
     3915. Remove the microSD card
     4016. Remove the boot jumper.
     4117. Power on the 825.
     4218. Confirm that 825 boots up showing the "Cardinal" startup screen
     43
     44By default a new install will have COM1 enabled for diagnostics.
     45This will interfere with apps using COM1 for other activities such as
     46bar code scanner. Perform the following steps to turn off COM1 console
     47mode.
     48
     491. Press "LEGAL METROLOGY INFORMATION / SETUP" button
     502. Press "SETUP MENU" button
     513. Press keyboard button to show on-screen keyboard and type "ADMIN"
     524. Press down arrow and type password "81440"
     535. Press "Communication" and "Comm Port 1 Defaults"
     546. Press down arrow repeatedly until "Console:" prompt is selected.
     557. Press "N" to set console to "No". Press "ENTER".
     56